Why Sun In The Box Uses LiFePO4 Batteries

Every system in the Sun In The Box line, from the 12 kWh home unit to the 200 kWh C&I cabinet, uses lithium iron phosphate (LiFePO4 or LFP) cells. Here is why.
Thermal stability
LFP chemistry is more thermally stable than nickel-based lithium chemistries. It is less prone to thermal runaway, which matters for batteries installed in homes, businesses and hot climates.
Long cycle life
LFP cells tolerate many charge and discharge cycles. Our datasheets list at least 8,000 cycles for the SIB-4KUS and at least 8,500 cycles (at 70% end of life) for the Sun In The Box X. For daily cycling, that means many years of service.
No cobalt or nickel
LFP cells do not use cobalt or nickel, which reduces supply-chain risk and cost.
What to check in any battery datasheet
Cycle life, and the end-of-life percentage it is measured at.
Usable capacity versus nominal capacity.
Certifications such as UN38.3, IEC 62619 and UL 1741.
The battery management system (BMS) and the safety protections.
LFP has a lower energy density than some other chemistries, so cabinets can be larger for the same capacity. For stationary storage, safety and lifetime usually matter more than weight.
Datasheets for the full line are on our Downloads page. Questions? Write to info@solsticesolarpower.com.